This Standard contains requirements for the design, selection and application of exterior cladding utilizing Exterior Insulation and Finish Systems (EIFS) that meet the requirements of CAN/ULC-S716.1, and for the interfaces between EIFS and other building components.

This Standard applies only to EIFS used in combination with a drained air space and liquid applied water resistive barrier (LA-WRB), as an exterior wall cladding system.

This Standard addresses the components forming the substrate to which the EIFS is attached only insofar as they impact the proper performance of the EIFS. This Standard does not address the structural design of the substrate.

Cladding systems where the reinforcement is the supporting element of the rendering, e.g., stucco, are not part of this Standard.

The use of mechanical fasteners is outside the scope of this Standard, – refer to Annex A for further information.

This document does not purport to address all the aspects related to EIFS design, selection and use. The use of this Standard requires a working knowledge of applicable federal, provincial and local building codes and regulations, as there may be other design, selection, or application considerations for specific installations that are not addressed by this standard.

This document is intended to provide detailed information pertaining to the design, selection and application of EIFS for building designers, building code officials, product manufacturers and contractors and to provide information that will promote satisfactory performance and durability of EIFS.

Product Details

Edition:
2
Published:
2012
ULC 716.3

ULC 716.3

Click here to purchase
This Standard contains requirements for the design, selection and application of exterior cladding utilizing Exterior Insulation and Finish Systems (EIFS) that meet the requirements of CAN/ULC-S716.1, and for the interfaces between EIFS and other building components.

This Standard applies only to EIFS used in combination with a drained air space and liquid applied water resistive barrier (LA-WRB), as an exterior wall cladding system.

This Standard addresses the components forming the substrate to which the EIFS is attached only insofar as they impact the proper performance of the EIFS. This Standard does not address the structural design of the substrate.

Cladding systems where the reinforcement is the supporting element of the rendering, e.g., stucco, are not part of this Standard.

The use of mechanical fasteners is outside the scope of this Standard, – refer to Annex A for further information.

This document does not purport to address all the aspects related to EIFS design, selection and use. The use of this Standard requires a working knowledge of applicable federal, provincial and local building codes and regulations, as there may be other design, selection, or application considerations for specific installations that are not addressed by this standard.

This document is intended to provide detailed information pertaining to the design, selection and application of EIFS for building designers, building code officials, product manufacturers and contractors and to provide information that will promote satisfactory performance and durability of EIFS.

Product Details

Edition:
3
Published:
2019

You may also like

ULC 701.1

ULC 701.1

Standard for Thermal Insulation, Polystyrene Boards (ULC S701.1)standard by Underwriters Laboratories of Canada, 02/25/2022

ULC 629

ULC 629

STANDARD FOR 650 °C FACTORY-BUILT CHIMNEYSstandard by Underwriters Laboratories of Canada, 04/07/2022

ULC 604

ULC 604

Standard for Factory-Built Type A Chimneysstandard by Underwriters Laboratories of Canada, 04/07/2022

ULC 628

ULC 628

Standard for Fireplace Inserts (ULC S628)standard by Underwriters Laboratories of Canada, 04/07/2022

Back to Top